FCW 250-O

Tubular wire for self-shielded metal arc hardfacing

Description & applications

Tubular wire for self-shielded metal arc hardfacing.

Surfacing or rebuilding parts subjected to high compression stresses and high impact.

FCW 250-O is used as buffer layer on ferritic steels before hardfacing with wires providing higher abrasion resistance or for rebuilding.

Classification

DIN 8555 EN 14700
MF1-GF-250-P T Fe1 250 P

Typical weld metal composition (%)

C Mn Si Cr Mo
0.10 1.50 0.70 1.50 0.20

All weld metal mechanical properties

Hardness - 3 Layer deposit
As welded : 250 HB

Shielding gas

Current type DC (+)
Shielding Self shielded

Operating conditions

Diameter [mm] Amperage [A] - Range Amperage [A] - Optimum Voltage [V] - Range Voltage [V] - Optimum Stick Out [mm] - Range Stick Out [mm] - Optimum
2.4 180-350 280 24-32 28 25-50 30
2.8 200-400 350 24-33 29 25-50 30
3.2 300-450 400 27-35 30 25-50 30

Welding positions

Flat, half up, half down

Packings & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Packing(s) Bobine BS 300 Couronne Drum
Weight [Kg] 15 kg 25 kg 330 kg
Description - - -