Tubular wire for self-shielded metal arc hardfacing
Tubular wire for self-shielded metal arc hardfacing.
Surfacing or rebuilding parts subjected to high compression stresses and high impact.
FCW 250-O is used as buffer layer on ferritic steels before hardfacing with wires providing higher abrasion resistance or for rebuilding.
DIN 8555 | EN 14700 |
---|---|
MF1-GF-250-P | T Fe1 250 P |
C | Mn | Si | Cr | Mo |
---|---|---|---|---|
0.10 | 1.50 | 0.70 | 1.50 | 0.20 |
Hardness - 3 Layer deposit |
---|
As welded : 250 HB |
Current type | DC (+) |
---|---|
Shielding | Self shielded |
Diameter [mm] | Amperage [A] - Range | Amperage [A] - Optimum | Voltage [V] - Range | Voltage [V] - Optimum | Stick Out [mm] - Range | Stick Out [mm] - Optimum |
---|---|---|---|---|---|---|
2.4 | 180-350 | 280 | 24-32 | 28 | 25-50 | 30 |
2.8 | 200-400 | 350 | 24-33 | 29 | 25-50 | 30 |
3.2 | 300-450 | 400 | 27-35 | 30 | 25-50 | 30 |
Flat, half up, half down
Diameters [mm] | ≤ 2.4 mm | ≥ 2.4 mm | ≥ 2.4 mm |
---|---|---|---|
Packing(s) | Bobine BS 300 | Couronne | Drum |
Weight [Kg] | 15 kg | 25 kg | 330 kg |
Description | - | - | - |