Tubular wire for self-shielded metal arc hardfacing
• Tubular wire for self-shielded metal arc hardfacing
• Chromium carbide type matrix with vanadium carbide particles dispersed uniformly throughout the deposit thickness
• For improving abrasion resistance: ideal complement to conventional chromium carbide deposits at the deposits at the final pass or for local reinforcement.
APPLICATIONS
FCW VN O is used for hardfacing components undergoing heavy wear by earth, sand or other abrasives. Relief checking is normal.
Examples
Used for mixer blades, extruder screws, crusher component armouring, tile and brick making equipment etc.
EN 14700 |
---|
T Fe16 |
C | Mn | Si | Cr | V | Fe |
---|---|---|---|---|---|
5.0 | 0.5 | 1.2 | 22.5 | 10.0 | Rest |
Hardness – 3-Layer deposit on mild steel |
---|
62-64 HRc |
Shielding gas | Self shielded |
---|---|
Current type | DC (+) |
Diameter [mm] | Amperage [A] -Range | Amperage [A] - Optimum | Voltage [V] - Range | Voltage [V] - Optimum | Stick-out [mm] - Range | Stick-out [mm] - Optimum |
---|---|---|---|---|---|---|
1.6 | 150-350 | 270 | 26-35 | 28 | 25-50 | 25 |
2.0 | 200-400 | 300 | 26-35 | 28 | 25-50 | 35 |
2.4 | 250-450 | 350 | 26-35 | 28 | 25-50 | 40 |
2.8 | 250-450 | 400 | 26-35 | 30 | 25-50 | 40 |
Flat, half up, half down
Diameters [mm] | 1.6 - 2.0 - 2.4 | 2.4 - 2.8 | 2.4 - 2.8 |
---|---|---|---|
Packing(s) | Spool BS 300 | Coil B450 | Drum |
Weight [Kg] | 15 | 25 | Up to 330 |
Description | - | - | - |