FCW L O

Cored wire for self-shielded metal arc hardfacing

Description & applications

• Tubular wire for self-shielded metal arc hardfacing

• Martensitic weld metal with good abrasion and impact resistance

• Self-tempering deposit for hardfacing

• Especially appliable in 2-3 layers for wear resistance

APPLICATIONS

FCW L O is used when good resistance to abrasion and impact in dry or wet environments is required.

Examples Bucket teeth, lips and undersides, cutting edges, steel mill rolls, cable drums, sand dredge equipment, dragline buckets, conveyor chutes, grizzly bars..

Classification

EN 14700
T Fe8

Typical weld metal composition (%)

C Mn Si Cr Fe
0.5 1.5 2.5 8.5 Rest

All weld metal mechanical properties

Hardness – 3-Layer deposit - As welded
56-59 HRc

Shielding gas

Current type DC (+)
Shielding Self shielded

Operating conditions

Diameter [mm] Amperage [A] - Range Amperage [A] - Optimum Voltage [V] - Range Voltage [V] - Optimum Stick-out [mm] - Range Stick-out [mm] - Optimum
1.2 100-300 250 21-35 28 12-25 20
1.6 150-300 270 24-35 28 15-25 25
2.0 200-400 300 26-35 28 20-50 30
2.4 250-450 350 26-35 28 25-50 40
2.8 250-450 400 28-35 30 25-50 40

Welding positions

Flat, half up, half down

Packings & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Packing(s) Spool : BS 300 Coil : B 450 Drum
Weight [Kg] 15 25 Up to 330 Kg
Description - - -
Copyright 2014 - Abracor SA - all right reserved