FCW FC

Tubular wire for self-shielded metal arc hardfacing

Description & applications

• Tubular wire for self-shielded metal arc hardfacing

• Chromium cast iron offering a good compromise in applications involving combined abrasion and impact

• Small diameter wires: flexibility of use with conventional medium-powered welding equipment

• The deposit contains a high proportion of hard primary chromium carbides in a tough austenitic matrix.

APPLICATIONS

FCW FC is used for hardfacing components undergoing wear by earth, sand and abrasives.

Examples

Crushers for soft materials, shredders, chemical and food processing industries.

Classification

DIN 8555 EN 14700
MF 10-GF-60-GR T ZFe

Typical weld metal composition (%)

C Mn Si Cr Fe
5.0 1.0 0.8 19.0 Rest

All weld metal mechanical properties

Hardness – 3-Layer deposit as welded
60 HRc

Shielding gas

Current type DC (+)
Shielding gas Self shielded

Operating conditions

Diameter [mm] Amperage [A] - Range Amperage [A] - Optimum Voltage [V] - Range Voltage [V] - Optimum Stick-out [mm] - Range Stick-out [mm] - Optimum
1.2 100-300 250 21-35 28 12-25 20
1.6 150-300 270 24-35 28 15-25 25
2.0 200-400 300 26-35 28 20-50 30
2.4 250-450 350 26-35 28 25-50 40
2.8 250-450 400 28-35 30 25-50 40

Welding positions

Flat, half up, half down

Packings & Diameters

Diameters [mm] 1.2 - 1.6 - 2.0 - 2.4 2.4 - 2.8 2.4 - 2.8
Packing(s) Spool BS300 Coil B 450 Drum
Weight [Kg] 15 25 Up to 330
Description - - -