Tubular wire for self-shielded metal arc hardfacing
• Tubular wire for self-shielded metal arc hardfacing
• Chromium cast iron offering a good compromise in applications involving combined abrasion and impact
• Small diameter wires: flexibility of use with conventional medium-powered welding equipment
• The deposit contains a high proportion of hard primary chromium carbides in a tough austenitic matrix.
APPLICATIONS
FCW FC is used for hardfacing components undergoing wear by earth, sand and abrasives.
Examples
Crushers for soft materials, shredders, chemical and food processing industries.
DIN 8555 | EN 14700 |
---|---|
MF 10-GF-60-GR | T ZFe |
C | Mn | Si | Cr | Fe |
---|---|---|---|---|
5.0 | 1.0 | 0.8 | 19.0 | Rest |
Hardness – 3-Layer deposit as welded |
---|
60 HRc |
Current type | DC (+) |
---|---|
Shielding gas | Self shielded |
Diameter [mm] | Amperage [A] - Range | Amperage [A] - Optimum | Voltage [V] - Range | Voltage [V] - Optimum | Stick-out [mm] - Range | Stick-out [mm] - Optimum |
---|---|---|---|---|---|---|
1.2 | 100-300 | 250 | 21-35 | 28 | 12-25 | 20 |
1.6 | 150-300 | 270 | 24-35 | 28 | 15-25 | 25 |
2.0 | 200-400 | 300 | 26-35 | 28 | 20-50 | 30 |
2.4 | 250-450 | 350 | 26-35 | 28 | 25-50 | 40 |
2.8 | 250-450 | 400 | 28-35 | 30 | 25-50 | 40 |
Flat, half up, half down
Diameters [mm] | 1.2 - 1.6 - 2.0 - 2.4 | 2.4 - 2.8 | 2.4 - 2.8 |
---|---|---|---|
Packing(s) | Spool BS300 | Coil B 450 | Drum |
Weight [Kg] | 15 | 25 | Up to 330 |
Description | - | - | - |