FCW 414-G

Tubular wire for gas shielded metal arc hardfacing

Description & applications

Tubular wire for gas shielded metal arc hardfacing.

13% chromium martensitic stainless steel deposit alloyed with Ni and Mo.

Hardfacing parts undergoing corrosion, oxidation, scaling and wear resistance.

Classification

EN 14700 DIN 8555
T Fe7 CZ MSG 5 GF 40 CZ

Typical weld metal composition (%)

C Mn Si Cr Ni Mo Fe
0.04 0.80 0.60 13.0 4.10 0.50 Bal.

All weld metal mechanical properties

Hardness - 3 Layer deposit
As welded : 38-42 HRc

Shielding gas

Current type DC (+)
Shielding gas EN ISO 14175 : M12 / M13 / M20 / M21

Operating conditions

Diameter [mm] Amperage [A] - Range Voltage [V] – Range Stick Out [mm] Gas flow [l/m]
1.2 100-300 24-32 12-25 10-20
1.6 150-300 24-32 12-25 10-20
2.0 200-400 24-32 12-30 10-20
2.4 250-450 24-32 12-30 10-20

Welding positions

Suitable as well for downhand as for positional welding by adapting transfer mode and welding parameters as for solid.

Packings & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Packing(s) Spool Coil Drum
Weight [Kg] 15 kg 25 kg 330 kg
Description - - -
Copyright 2014 - Abracor SA - all right reserved