• Cobalt base tubular wire for gas shielded metal arc hardsurfacing
• Exceptional resistance to metal-to-metal wear in corrosive media at high temperatures, where shocks are low to moderate
APPLICATIONS
FCW 1 is used for hardsurfacing parts undergoing the single or combined effects of heavy metal-to-metal wear or abrasion, temperatures ranging from RT to 800°C and corrosive environments.
Examples Steam valves, wire guides, rubber and plastic mixers, extrusion screws, conveyors…
EN 14700 | AWS A 5.21 |
---|---|
T Co3 | ERCCoCr-C |
C | Mn | Si | Cr | W | Fe | Co |
---|---|---|---|---|---|---|
2.3 | 1.0 | 1.0 | 29.0 | 12.0 | 4.0 | Bal. |
Hardness - as welded | High temperature hardness - 20°C | High temperature hardness - 200°C | High temperature hardness - 400°C | High temperature hardness - 600°C | High temperature hardness - 800°C |
---|---|---|---|---|---|
53 HRc | 560 HB | 540HB | 480 HB | 400 HB | 220 HB |
Current type | DC+ or pulsed |
---|---|
EN 439 / ISO 14175 | I1 (argon), M13 (Ar+1à 2 % O2) |
Gas flow rate | 10 - 20 l/min |
Diameter [mm] | Amperage [A] - Range | Amperage [A] - Optimum | Voltage [V] - Range | Voltage [V] - Optimum | Stick-out [mm] - Range | Stick-out [mm] - Optimum |
---|---|---|---|---|---|---|
1.2 | 100-250 | 200 | 15-30 | 28 | 15-30 | 10-20 |
1.6 | 140-350 | 250 | 15-30 | 28 | 15-30 | 10-20 |
Flat, half up, half down
Diameters [mm] | ≤ 2.4 mm | ≥ 2.4 mm | ≥ 2.4 mm |
---|---|---|---|
Packing(s) | Spool : BS 300 | Coil : B 450 | Drum |
Weight [Kg] | 15 | 25 | Up to 330 |
Description | - | - | - |