Description & applications

• Cobalt base tubular wire for gas shielded metal arc hardsurfacing

• Exceptional resistance to metal-to-metal wear in corrosive media at high temperatures, where shocks are low to moderate

APPLICATIONS

FCW 1 is used for hardsurfacing parts undergoing the single or combined effects of heavy metal-to-metal wear or abrasion, temperatures ranging from RT to 800°C and corrosive environments.

Examples Steam valves, wire guides, rubber and plastic mixers, extrusion screws, conveyors…

Classification

EN 14700 AWS A 5.21
T Co3 ERCCoCr-C

Typical weld metal composition (%)

C Mn Si Cr W Fe Co
2.3 1.0 1.0 29.0 12.0 4.0 Bal.

All weld metal mechanical properties

Hardness - as welded High temperature hardness - 20°C High temperature hardness - 200°C High temperature hardness - 400°C High temperature hardness - 600°C High temperature hardness - 800°C
53 HRc 560 HB 540HB 480 HB 400 HB 220 HB

Shielding gas

Current type DC+ or pulsed
EN 439 / ISO 14175 I1 (argon), M13 (Ar+1à 2 % O2)
Gas flow rate 10 - 20 l/min

Operating conditions

Diameter [mm] Amperage [A] - Range Amperage [A] - Optimum Voltage [V] - Range Voltage [V] - Optimum Stick-out [mm] - Range Stick-out [mm] - Optimum
1.2 100-250 200 15-30 28 15-30 10-20
1.6 140-350 250 15-30 28 15-30 10-20

Welding positions

Flat, half up, half down

Packings & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Packing(s) Spool : BS 300 Coil : B 450 Drum
Weight [Kg] 15 25 Up to 330