FCW 19 9 6 S

Tubular wire for submerged arc hardfacing

Description & applications

• Tubular wire for submerged arc hardfacing

• Austenitic stainless weld deposit

• Good impact, cavitation and corrosion resistance

• The weld deposit work hardens to different degrees depending on amount of impact

• Resists scaling up to 850°C, good resistance to thermal shocks

APPLICATIONS

• FCW 19 9 6 G is mainly used to rebuild components exposed to high impact and corrosion.

• Sub-layer before hardfacing

Examples Steel mill rolls, metallurgical plant guides, tram and train rails and fittings, high speed forming rolls

Classification

EN 14700
T Fe10

Typical weld metal composition (%)

C Mn Si Cr Ni
0.1 6.0 0.5 19.0 9.0

All weld metal mechanical properties

Hardness – 3-Layer deposit - As welded Hardness – 3-Layer deposit - Work hardened
180 HB 47 HRc

Shielding gas

Current type DC (+)
Shielding WAF 325 or WAF 385

Operating conditions

Diameter [mm] Amperage [A] - Range Amperage [A] - Optimum Voltage [V] - Range Voltage [V] - Optimum Stick-out [mm] - Range Stick-out [mm] - Optimum
1.6 150-300 250 26-32 30 15-30 25
2.0 200-350 270 26-32 30 20-50 25
2.4 200-450 350 26-32 30 25-50 30
2.8 250-550 400 28-32 30 25-50 30
3.2 300-650 500 28-32 30 25-50 30

Welding positions

Flat

Packings & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Packing(s) Spool : BS 300 Coil : B 450 Drum
Weight [Kg] 15 25 Up to 330 kg
Description - - -