FCW WMoLC

Metal-cored hardfacing wire for gas shielded arc welding

Description & applications

• Metal-cored hardfacing wire for gas shielded arc welding

• Crack-free rebuilding of forge tooling

• Suited to service temperatures up to 650°C

APPLICATIONS

FCW WMoLC is specially designed for repair of forging dies. Large surfaces are hardfaced with the softer FCW VMoLC to avoid cracks. Smaller areas and details that are subject to high levels of stress and abrasion are reconstituted using the harder FCW WMoLC.

The choice is a compromise between optimum hardness and the need to resist fatigue, abrasion and cracking.

Normal precautions are to be observed during welding: removal of damaged zones, preheating, correct operating temperatures and post-weld heat treatment.

Classification

EN 14700
T Fe3

Typical weld metal composition (%)

C Mn Si Cr Mo W V Fe
0.3 0.8 0.6 6.5 2.0 2.0 0.6 Rest

All weld metal mechanical properties

Hardness – all weld metal analysis
50 - 54 HRc

Shielding gas

Current type DC (+)
Shielding gas EN ISO 14175 : M12 / M13 / M20 / M21

Operating conditions

Diameter [mm] Amperage [A] Voltage [V] Stick-out [mm] Gas flow [l/min] Recovery
1.2 100-300 24-32 12-25 10-20 > 95 %
1.6 150-300 24-32 12-25 10-20 > 95 %
2.0 200-400 24-32 12-30 10-20 > 95 %
2.4 250-450 24-32 12-30 10-20 > 95 %

Welding positions

FCW WMoLC, up to Ø 1.6 mm, is suitable for downhand as well as for positional welding by adapting transfer mode and welding parameters as for solid wires

Packings & Diameters

Diameters [mm] 1.2 - 1.6 - 2.0 - 2.4 2.4 2.4
Packing(s) Spool BS 300 Coil B 450 Drum
Weight [Kg] 15 25 Up to 330
Description - - -