• Metal cored stainless steel wire for gas shielded arc welding
• 25% chromium - 20% nickel deposit • Enhanced productivity, improved weldability, better wetting properties compared to solid wires
• Excellent weld metal quality and X-ray soundness
APPLICATIONS
FCW Sub 310 is resistant to oxidation and scaling up to 1100°C. It is suitable for welding cast or wrought stainless steels of similar composition and heat resistant ferritic stainless steels.
Examples
AISI |
UNS |
Material number |
EN Symbol |
310 |
S31000 |
1.4841 |
X15 CrNiSi 25-21 |
310S |
S31008 |
1.4845 |
X12 CrNi 25-21 |
AWS A 5.9 | EN ISO 17633-A: |
---|---|
EC310 | T 25 20 M M 1 |
C | Mn | Si | Cr | Ni |
---|---|---|---|---|
0.15 | 4.00 | 0.60 | 26.0 | 20.5 |
Rm (MPa) | Rp0.2% (MPa) | A5 (%) | KCV (J) |
---|---|---|---|
630 | 420 | 30 | 20°C : 70 |
EN ISO 14175 | M12 Ar + 0.5 % < CO2 ≤ 2.5 with or without Helium – Z Ar + CO2 ≤ 0.5 % or O2 ≤ 0.5 % with or without Helium – M20 Ar + 5 % < CO2 ≤ 15 – I1 Ar – M13 Ar + 0.5 % < O2 ≤ 3.0 with or without Helium |
---|
Current type | Gas flow rate | Stick out (mm) | Recovery |
---|---|---|---|
DC (+)/pulsed | 10-20 l/min. | 12-25 | 98% |
EN ISO 6947:PA, PB.
ASME IX:1F, 1G, 2F.
FCW Sub 310 is primarily used in the flat and horizontal-vertical positions. However, welds in other positions are also possible using the short-circuiting or pulsed arc modes of transfer.
Diameters [mm] | 1.2 | 1.2 - 1.6 |
---|---|---|
Packing(s) | Spool S200 | Spool BS300 |
Weight [Kg] | 5 | 15 |
Description | - | - |