Cast iron
· Flux cored wire for semi-automatic gas shielded arc welding.
· Designed for welding grey, malleable, nodular and phosphorous cast iron.
· Also used to for dissimilar weldments between cast iron and steel.
· Welding of highly restrained or thick walled pieces
· Preheat is not necessary. Heat input is low which favours limited H.A.Z.
APPLICATIONS
· Joining and repairing all types of cast iron
EN ISO 1071 |
---|
T C NiFe-2 |
C | Mn | Si | Ni | Fe |
---|---|---|---|---|
0.75 | 4.00 | 0.60 | 45.0 | Bal. |
Rm (MPa) | Rp0.2%(MPa) | A % | Hardness (HB) |
---|---|---|---|
550 | 340 | 16 | 165 |
M21 according to EN 439 | ISO 14175 (Argon + 5 to 25% CO²) |
---|
Diameter [mm] | Current type | Amperage [A] | Voltage [V] | Stick Out [mm] | Gas flow |
---|---|---|---|---|---|
1.2 | DC (+) | 180-250 | 20-26 | 12-25 | 10-20 l/min |
1.6 | DC (+) | 180-350 | 22-26 | 12-25 | 10-20 l/min |
EN ISO 6947: PA, PB
ASME IX: 1G, 1FDiameters [mm] | 1.2 - 1.6 |
---|---|
Packing(s) | Spool BS300 |
Weight [Kg] | 15 kg |
Description | - |