Tubular wire for gas shielded metal arc hardfacing
Tubular wire for gas shielded metal arc hardfacing.
Low alloy martensitic deposit.
FCW 350-G is used for surfacing and rebuilding parts subjected to impact and high compressive stresses.
EN 14700 | DIN 8555 |
---|---|
T Fe1 350 P | MSG 1 GF 350 P |
C | Mn | Si | Cr | Mo | Fe |
---|---|---|---|---|---|
0.15 | 1.50 | 0.70 | 2.00 | 0.20 | Bal. |
Hardness - 3 Layer deposit |
---|
As welded : 350 HB |
Current type | DC (+) |
---|---|
Shielding gas | EN ISO 14175 : M12 / M13 / M21 |
Diameter [mm] | Amperage [A] - Range | Voltage [V] – Range | Stick Out [mm] |
---|---|---|---|
1.2 | 100-300 | 24-32 | 12-25 |
1.6 | 150-300 | 24-32 | 12-25 |
2.0 | 200-400 | 24-32 | 12-30 |
2.4 | 250-450 | 24-32 | 12-30 |
Suitable as well for downhand as for positional welding by adapting transfer mode and welding parameters as for solid wires.
Diameters [mm] | ≤ 2.4 mm | ≥ 2.4 mm | ≥ 2.4 mm |
---|---|---|---|
Packing(s) | Spool | Coil | Drum |
Weight [Kg] | 15 kg | 25 kg | 330 kg |
Description | - | - | - |